ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
DMHFP : เครื่องวัดอัตราการไหลแบบอัลตร้าโซนิค+หัววัดอุณหภูมิ
ข้อมูลสินค้า
-
รหัสสินค้า
DMHFP
-
เข้าชม
2,872 ครั้ง
ยี่ห้อ
DYNAMETER
รุ่น
DMHFP
-
แก้ไขล่าสุดเมื่อ
29/04/2019 15:21
-
รายละเอียดสินค้า
GENERAL :
The DMHFP adopt the MultiPulseTM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement technology, with a measuring system of very high accuracy, versatility, low cost of installation and ownership. The meter can calculate automatically caloric content of water under carious temperatures, and can obtain instantaneous caloric value and totalized caloric value. The Non-invasive clamp-on series and the Insertion series are available. Users can select fixed types or Portable types. The pipe range should be 25mm-2540mm (For Insertion series, the allowed pipe range is 65mm-2540mm) TECHNICAL SPECIFICATION : ▪ Non-invasive clamp-on series transducer and Insertion eries transducer are available. ▪ Internally configured batch controller makes batch control convenient and accurate. ▪ No moving parts, no pressure drop, no need of maintenance. ▪ Easy and economical installation, hot-tapped installation. ▪ Daily, monthly and yearly totalized flow: totalized flow for the last 64 days and months as well as for the last 5 years can be reviewed. ▪ Optional SD card Data logger output, can memory total Heat Flow, Heat flow rate, etc. Transmitter Power Supply (Std) 10-28 VDC @ 2.5VA max.115/230VAC 50/60Hz ±15%@ 5VAmax. or rechargeable battery. Velocity 0 to ±40 ft/s (0 to ±12m/s), bi-directional Display 4 line X 16 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc. Units User Configured (English and Metric); Rate Rate and Velocity Display; Totalized (FWD, NET, REV or BATCH) gallons, ft³, barrels, lbs, litters, m³,kg Output 4 to 20mA, Pulse, Relay, RS232C or RS485, options: up to 8 GB Data logger, Hart +(4 to 20mA), Modbus Accuracy ±1.0% of reading at rates >0.5 m/s ±2.0% of reading at rates <0.5 m/s Sensitivity Flow Rate: 0.001ft/s (0.0003m/s) Repeatability 0.2% of reading Security Keypad lockout, access code enable Transducer Liquid Types Virtually most any liquid containing less than 2% Supported total suspended solids (TSS) or aeration Suited Liquid Std. Temp. Transducer : -40 Deg C to 121Deg C Temperature High Temp. Transducer : -40 Deg C to 250Deg C Cable Length Std: 20 feet (6m); Opt: Maximum: 990 feet (300m) Dimensions S: Size : 42*25*25; weight:<0.3kg and Weight M: Size : 60*43*43; weight:<0.6kg L: Size : 80*53*53; weight:<1.0kg Pipe Size L transducer: DN1000 - 4500 M transducer: DN40 -1000 S transducer: DN15 - 50 Insertion transducer: DN65 – 2500 Flanged transducer: DN65 – 2500 Temperature Temperature C1-Pt100 : (-40~150℃) Two-Wire System Temperature Sensor Input Type transmitter input C2-Pt1000 : (-40~150℃) Two-Wire System Temperature transmitter input
Tags : เครื่องวัดอัตราการไหล , เครื่องวัดอัตราการไหลแบบอัลตร้าโซนิค , หัววัดอุณหภูมิ , เครื่องมือวัด , DMHFP , DYNAMETER , Ultrasonic Flow Meter Temperature